Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Use of Incinerators in Farms and Livestock Facilities in Africa

Use of Incinerators in Farms and Livestock Facilities in Africa: Applications and Environmental Benefits


1. Context: Agricultural Waste Challenges in Africa

In Africa, large and medium-scale farms—including:

  • Poultry farms (broiler and layer operations)

  • Dairy farms (milk production units)

  • Goat, sheep, and pig farms

routinely generate significant volumes of animal by-products and organic waste, such as:

  • Dead birds, mortalities, and animal carcasses

  • Hatchery waste (egg shells, non-viable embryos)

  • Manure mixed with bedding materials

  • Placental and birthing waste in dairy operations

Without proper disposal, these wastes pose serious biosecurity risks, including:

  • Disease spread (avian influenza, Newcastle disease, foot-and-mouth disease, brucellosis)

  • Contamination of surface and groundwater

  • Bad odors and attraction of scavengers or vermin


2. Application of Incinerators on Farms

Incinerators are widely used on:

  • Commercial poultry farms with 5,000+ birds

  • Large dairy operations with 100+ head of cattle

  • Abattoirs and slaughterhouses associated with farms

They typically burn:

  • Mortalities

  • Veterinary waste (used syringes, gloves, medication packaging)

  • Small amounts of packaging and organic farm waste

In Africa, countries including South Africa, Kenya, Nigeria, Egypt, and Morocco have farms using small and medium-sized incinerators, often:

  • Locally made batch-fed units (5–50 kg/hour)

  • Containerized models (e.g., HICLOVER TS30–TS100 PLC series)

  • Dual-chamber designs to reduce smoke and odor


3. Environmental Advantages of Farm-Based Incineration

a) Disease Control and Biosecurity

  • Immediate destruction of pathogens in carcasses and hatchery waste

  • Reduces the risk of outbreaks that threaten farm profitability and regional food security

b) Reduction of Groundwater Contamination

  • Prevents the need for burial pits or open dumping, which can leach bacteria and nutrients (like nitrogen and phosphorus) into soil and water tables

c) Odor and Vector Control

  • Proper high-temperature incineration eliminates the organic load that would otherwise attract flies, rodents, and scavenger birds

d) Greenhouse Gas Benefits vs. Open Burning

  • Controlled combustion in modern dual-chamber units burns cleaner than traditional open fires

  • Significantly lowers methane emissions compared to carcass burial in anaerobic conditions

e) Volume Reduction

  • Incineration can reduce animal by-product volume by over 95%, leaving small quantities of inert ash that can be disposed of safely


4. Technical Features for African Farms (HICLOVER Focus)

HICLOVER offers solutions specifically adapted for agricultural operations:

  • Capacity: 10–100 kg/hour (ideal for daily farm waste volumes)

  • Dual-chamber combustion (>850°C in secondary chamber)

  • Containerized and trailer-mounted models for flexible placement

  • PLC control systems for safe, semi-automated operation

  • Heavy refractory lining to withstand frequent daily burning cycles

  • Optional wet scrubbers to reduce odor and visible smoke

In larger commercial operations, HICLOVER’s TS100–TS200 PLC models have been used to handle mortalities in poultry houses of 30,000+ birds, or large dairy farms experiencing seasonal mortality spikes.


5. Market Trend and Adoption in Africa

  • Growing adoption driven by stricter veterinary health regulations (e.g., Kenya’s Animal Disease Act, South Africa’s Animal Health Act)

  • Donor and government support: Some poultry value-chain development projects in Nigeria and Kenya include co-financing for on-farm incinerators

  • Export market: African farms increasingly purchase containerized Chinese-made models (like HICLOVER) due to competitive pricing and quick delivery


In Africa’s agriculture, incinerators are no longer optional—they are an essential tool for:

  • Protecting livestock health and farm revenue

  • Preventing disease outbreaks

  • Minimizing environmental impact

HICLOVER’s compact, high-temperature, dual-chamber incinerators help farms comply with regulations, reduce biosecurity risks, and contribute to a cleaner, safer agricultural environment.

Mobile: +86-13813931455(WhatsApp)

Email:     sales@hiclover.com     

HICLOVER TS20 PLC Hospital Waste Incinerator Delivered to Togo: Safe, Efficient, and Fully Automated Solution

HICLOVER is proud to announce the successful deployment of its TS20 PLC model hospital waste incinerator in Togo, tailored for safe and reliable medical waste disposal. Designed to meet global environmental and health safety standards, the HICLOVER TS20 PLC incinerator is a compact, high-performance system ideal for hospitals, clinics, and healthcare facilities requiring dependable, on-site waste management.


High-Temperature, Complete Combustion

The TS20 PLC model ensures complete combustion at temperatures above 1000°C, effectively destroying all pathogens and harmful substances found in hospital waste. With a dual combustion chamber system and high exhaust temperatures exceeding 1300°C, it guarantees safe and clean incineration, reducing waste to a sterile ash residue.


Superior Construction for High-Performance Operation

  • Flame-retardant lining withstands up to 1750°C, ensuring durability and operational safety.

  • Thermostatic temperature control optimizes fuel efficiency and maintains consistent thermal performance.

  • Sturdy body weight of around 2000kg ensures stable operation in various environments.

  • External dimensions: 2150 x 1200 x 1100 mm; Main chamber: 800 x 800 x 350 mm.

  • Chimney height of approximately 6 meters ensures proper exhaust dispersion.


Practical Waste Handling Capacity

  • Incineration rate: 5 to 20 kg of waste per hour, with daily capacity up to 150 kg (330 lbs).

  • Chamber volume: up to 8 cubic feet (0.22 cubic meters) per load.

  • Built-in 50-gallon (200L) fuel tank supports continuous operation in remote or resource-constrained settings.


Advanced Automation & Easy Operation

  • Automatic, pre-set cycle control for both startup and shutdown ensures minimal human intervention.

  • State-of-the-art PLC control system offers simple interface and real-time temperature monitoring.

  • Minimal training required C the system is ready to use upon delivery, saving time and resources.

  • Modular design simplifies on-site transport, assembly, and maintenance.


Ideal Solution for Medical Waste in Togo and Beyond

The HICLOVER TS20 PLC hospital waste incinerator is now operational in Togo, supporting safer healthcare environments by eliminating infectious waste at the point of generation. It is a proven solution for rural and urban hospitals alike, especially where centralized waste treatment is not available.


 Learn More About HICLOVER

Explore how HICLOVER incinerators can serve your hospital, NGO project, or emergency response unit. Our equipment meets WHO and UN procurement standards, with a proven track record across Africa, the Middle East, and Asia.

Visit www.hiclover.com
 Email: info@hiclover.com


Related Keywords for SEO

  • Hospital waste incinerator in Togo

  • Medical incineration system Africa

  • HICLOVER TS20 PLC incinerator

  • Dual chamber medical waste burner

  • Portable incinerator for healthcare waste

  • High-temperature incinerator for pathogens

  • WHO-compliant incinerators

  • On-site medical waste disposal solution

Mobile: +86-13813931455(WhatsApp)

Email:     sales@hiclover.com     

PLC based control box for incinerator

i.   Circular Mild Steel / Stainless steel with minimum thickness
3mm, self-supported flange section chimney and should have suitable door/window at the base for cleaning.
ii. Proper port for taking exhaust gases sample to monitor emission levels as per international standards provided with a cover to be opened and closed when needed without affecting the function of chimney.
iii. Chimney should have height of at-least 15 meters from ground
level. incinerating waste
small scale incinerator
portable waste incinerator
10.     Electrical Control
i. PLC based control box with hinged sealed door, pre-installed control circuitry should be rugged enough to withstand the temperature effect of the incinerator.
ii. It should house the ignition burner time, feed interval timer, shutdown timer post combustion chamber temperature controller, control for burner, blower fans and gas washer.
iii. Digital display of temperature and set timing parameters.

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

About Us HICLOVER

HICLOVER is growing brand for environmental protection field, and market share with most of Africa,
Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner
for governmental organizations, non-profit organizations, international contractors, logistics organizations,
military, pet cremation business owners, etc. We have export experience more than 40 countries, including
war zone like Iraq, Afghanistan, Somalia, South Sudan.
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for
incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog
incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable
incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator.
HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly
service.

Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC)
Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic PLC Automatic PLC Automatic
Combustion Chamber 52L 100L 210L 330L
Internal Dimensions 50x35x30cm 50x50x40cm 65x65x50cm 75x75x60cm
Secondary Chamber 26L 50L 110L 180L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 2P 220V 2P 220V 2P 220V 2P
Power 0.5Kw 0.5Kw 0.5Kw 0.5Kw
Burner Type Italy Brand Italy Brand Italy Brand Italy Brand
Oil Consumption (kg/hour) 4 6 8 12
Gas Consumption (m3/hour) 6.2-11.4 6.2-11.4 8-15.7 9.8–20
Temperature Monitor Yes Yes Yes Yes
Temperature Thermometer Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube
Temperature Protection Yes Yes Yes Yes
Automatic Cooling Yes Yes Yes Yes
Automatic False Alarm  Yes Yes Yes Yes
System Testing Model Yes Yes Yes Yes
Time Setting Yes Yes Yes Yes
Progress Display Bar LCD Display LCD Display LCD Display LCD Display
Oil Tank 200L 200L 200L 200L
Oil Tank Stand 190cm Height 190cm Height 190cm Height 190cm Height
Liquid level Display  Yes Yes Yes Yes
Feeding Door 20x20cm 30x30cm 45x40cm 55x50cm
Chimney 2Meter 3Meter 3Meter 5Meter
Chimney Type Stainless Steel 304  Stainless Steel 304  Stainless Steel 304  Stainless Steel 304 
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1000kg 1500kg 2200kg 3000kg
External Dimensions 120x80x110cm 140x90x120cm 160x110x130cm 175x120x140cm

Top Feeding Door Solid Waste Incinerators HICLOVER

HICLOVER Top Feeding Door Waste Incinerators

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke




parts of an incinerator
physical method of disposing hazardous chemical waste
portable incinerators types
proper ways of waste disposal in the community
questionnaire to ask about incinerators for collection of data

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-08-07

Clover's Social Media