Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Use of Incinerators in Farms and Livestock Facilities in Africa
Use of Incinerators in Farms and Livestock Facilities in Africa: Applications and Environmental Benefits
1. Context: Agricultural Waste Challenges in Africa
In Africa, large and medium-scale farms—including:
-
Poultry farms (broiler and layer operations)
-
Dairy farms (milk production units)
-
Goat, sheep, and pig farms
routinely generate significant volumes of animal by-products and organic waste, such as:
-
Dead birds, mortalities, and animal carcasses
-
Hatchery waste (egg shells, non-viable embryos)
-
Manure mixed with bedding materials
-
Placental and birthing waste in dairy operations
Without proper disposal, these wastes pose serious biosecurity risks, including:
-
Disease spread (avian influenza, Newcastle disease, foot-and-mouth disease, brucellosis)
-
Contamination of surface and groundwater
-
Bad odors and attraction of scavengers or vermin
2. Application of Incinerators on Farms
Incinerators are widely used on:
-
Commercial poultry farms with 5,000+ birds
-
Large dairy operations with 100+ head of cattle
-
Abattoirs and slaughterhouses associated with farms
They typically burn:
-
Mortalities
-
Veterinary waste (used syringes, gloves, medication packaging)
-
Small amounts of packaging and organic farm waste
In Africa, countries including South Africa, Kenya, Nigeria, Egypt, and Morocco have farms using small and medium-sized incinerators, often:
-
Locally made batch-fed units (5–50 kg/hour)
-
Containerized models (e.g., HICLOVER TS30–TS100 PLC series)
-
Dual-chamber designs to reduce smoke and odor
3. Environmental Advantages of Farm-Based Incineration
a) Disease Control and Biosecurity
-
Immediate destruction of pathogens in carcasses and hatchery waste
-
Reduces the risk of outbreaks that threaten farm profitability and regional food security
b) Reduction of Groundwater Contamination
-
Prevents the need for burial pits or open dumping, which can leach bacteria and nutrients (like nitrogen and phosphorus) into soil and water tables
c) Odor and Vector Control
-
Proper high-temperature incineration eliminates the organic load that would otherwise attract flies, rodents, and scavenger birds
d) Greenhouse Gas Benefits vs. Open Burning
-
Controlled combustion in modern dual-chamber units burns cleaner than traditional open fires
-
Significantly lowers methane emissions compared to carcass burial in anaerobic conditions
e) Volume Reduction
-
Incineration can reduce animal by-product volume by over 95%, leaving small quantities of inert ash that can be disposed of safely
4. Technical Features for African Farms (HICLOVER Focus)
HICLOVER offers solutions specifically adapted for agricultural operations:
-
Capacity: 10–100 kg/hour (ideal for daily farm waste volumes)
-
Dual-chamber combustion (>850°C in secondary chamber)
-
Containerized and trailer-mounted models for flexible placement
-
PLC control systems for safe, semi-automated operation
-
Heavy refractory lining to withstand frequent daily burning cycles
-
Optional wet scrubbers to reduce odor and visible smoke
In larger commercial operations, HICLOVER’s TS100–TS200 PLC models have been used to handle mortalities in poultry houses of 30,000+ birds, or large dairy farms experiencing seasonal mortality spikes.
5. Market Trend and Adoption in Africa
-
Growing adoption driven by stricter veterinary health regulations (e.g., Kenya’s Animal Disease Act, South Africa’s Animal Health Act)
-
Donor and government support: Some poultry value-chain development projects in Nigeria and Kenya include co-financing for on-farm incinerators
-
Export market: African farms increasingly purchase containerized Chinese-made models (like HICLOVER) due to competitive pricing and quick delivery
In Africa’s agriculture, incinerators are no longer optional—they are an essential tool for:
-
Protecting livestock health and farm revenue
-
Preventing disease outbreaks
-
Minimizing environmental impact
HICLOVER’s compact, high-temperature, dual-chamber incinerators help farms comply with regulations, reduce biosecurity risks, and contribute to a cleaner, safer agricultural environment.
HICLOVER TS20 PLC Hospital Waste Incinerator Delivered to Togo: Safe, Efficient, and Fully Automated Solution
HICLOVER is proud to announce the successful deployment of its TS20 PLC model hospital waste incinerator in Togo, tailored for safe and reliable medical waste disposal. Designed to meet global environmental and health safety standards, the HICLOVER TS20 PLC incinerator is a compact, high-performance system ideal for hospitals, clinics, and healthcare facilities requiring dependable, on-site waste management.
High-Temperature, Complete Combustion
The TS20 PLC model ensures complete combustion at temperatures above 1000°C, effectively destroying all pathogens and harmful substances found in hospital waste. With a dual combustion chamber system and high exhaust temperatures exceeding 1300°C, it guarantees safe and clean incineration, reducing waste to a sterile ash residue.
Superior Construction for High-Performance Operation
-
Flame-retardant lining withstands up to 1750°C, ensuring durability and operational safety.
-
Thermostatic temperature control optimizes fuel efficiency and maintains consistent thermal performance.
-
Sturdy body weight of around 2000kg ensures stable operation in various environments.
-
External dimensions: 2150 x 1200 x 1100 mm; Main chamber: 800 x 800 x 350 mm.
-
Chimney height of approximately 6 meters ensures proper exhaust dispersion.
Practical Waste Handling Capacity
-
Incineration rate: 5 to 20 kg of waste per hour, with daily capacity up to 150 kg (330 lbs).
-
Chamber volume: up to 8 cubic feet (0.22 cubic meters) per load.
-
Built-in 50-gallon (200L) fuel tank supports continuous operation in remote or resource-constrained settings.
Advanced Automation & Easy Operation
-
Automatic, pre-set cycle control for both startup and shutdown ensures minimal human intervention.
-
State-of-the-art PLC control system offers simple interface and real-time temperature monitoring.
-
Minimal training required C the system is ready to use upon delivery, saving time and resources.
-
Modular design simplifies on-site transport, assembly, and maintenance.
Ideal Solution for Medical Waste in Togo and Beyond
The HICLOVER TS20 PLC hospital waste incinerator is now operational in Togo, supporting safer healthcare environments by eliminating infectious waste at the point of generation. It is a proven solution for rural and urban hospitals alike, especially where centralized waste treatment is not available.
Learn More About HICLOVER
Explore how HICLOVER incinerators can serve your hospital, NGO project, or emergency response unit. Our equipment meets WHO and UN procurement standards, with a proven track record across Africa, the Middle East, and Asia.
Visit www.hiclover.com
Email: info@hiclover.com
Related Keywords for SEO
-
Hospital waste incinerator in Togo
-
Medical incineration system Africa
-
HICLOVER TS20 PLC incinerator
-
Dual chamber medical waste burner
-
Portable incinerator for healthcare waste
-
High-temperature incinerator for pathogens
-
WHO-compliant incinerators
-
On-site medical waste disposal solution
PLC based control box for incinerator

Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | |
Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 100L | 210L | 330L | 560L | |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | |
Secondary Chamber | 50L | 110L | 180L | 280L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 0.75Kw | 0.83Kw | 0.99Kw | 1.2Kw | |
Diesel Oil Consumption (kg/hour) | Ave.8.4 | Ave.10.9 | Ave.13.3 | Ave.16.9 | |
Natural Gas Consumption (m3n/hour) | Ave.10.1 | Ave.13 | Ave.16 | Ave.20.2 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes | |
Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) | |
Burn Rate (Average) | 100 kg/hour | 150 kg/hour | 300 kg/hour | 500 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 1200L | 1500L | 2000L | 3000L | |
Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm | |
Secondary Chamber | 600L | 750L | 1000L | 1500L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw | |
Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 | |
Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes |
About Us HICLOVER

Incinerator Items/Model | HICLOVER TS5(PLC) | HICLOVER TS10(PLC) | HICLOVER TS20(PLC) | HICLOVER TS30(PLC) |
Burn Rate (Average) | 5-10 kg/hour | 10-20 kg/hour | 20-30 kg/hour | 30-50 kg/hour |
Feed Capacity(Average) | 10kg/feeding | 20kg/feeding | 40kg/feeding | 60kg/feeding |
Control Mode | PLC Automatic | PLC Automatic | PLC Automatic | PLC Automatic |
Combustion Chamber | 52L | 100L | 210L | 330L |
Internal Dimensions | 50x35x30cm | 50x50x40cm | 65x65x50cm | 75x75x60cm |
Secondary Chamber | 26L | 50L | 110L | 180L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual |
Voltage | 220V 2P | 220V 2P | 220V 2P | 220V 2P |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.5Kw |
Burner Type | Italy Brand | Italy Brand | Italy Brand | Italy Brand |
Oil Consumption (kg/hour) | 4 | 6 | 8 | 12 |
Gas Consumption (m3/hour) | 6.2-11.4 | 6.2-11.4 | 8-15.7 | 9.8–20 |
Temperature Monitor | Yes | Yes | Yes | Yes |
Temperature Thermometer | Corundum Probe Tube | Corundum Probe Tube | Corundum Probe Tube | Corundum Probe Tube |
Temperature Protection | Yes | Yes | Yes | Yes |
Automatic Cooling | Yes | Yes | Yes | Yes |
Automatic False Alarm | Yes | Yes | Yes | Yes |
System Testing Model | Yes | Yes | Yes | Yes |
Time Setting | Yes | Yes | Yes | Yes |
Progress Display Bar | LCD Display | LCD Display | LCD Display | LCD Display |
Oil Tank | 200L | 200L | 200L | 200L |
Oil Tank Stand | 190cm Height | 190cm Height | 190cm Height | 190cm Height |
Liquid level Display | Yes | Yes | Yes | Yes |
Feeding Door | 20x20cm | 30x30cm | 45x40cm | 55x50cm |
Chimney | 2Meter | 3Meter | 3Meter | 5Meter |
Chimney Type | Stainless Steel 304 | Stainless Steel 304 | Stainless Steel 304 | Stainless Steel 304 |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1300℃ | 1000℃-1300℃ | 1000℃-1300℃ | 1000℃-1300℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1000kg | 1500kg | 2200kg | 3000kg |
External Dimensions | 120x80x110cm | 140x90x120cm | 160x110x130cm | 175x120x140cm |
Top Feeding Door Solid Waste Incinerators HICLOVER
HICLOVER Top Feeding Door Waste Incinerators▲▲▲Large Feeding Door▲▲▲Better for Animal Waste Cremation▲▲▲HICLOVER Brand Section***Primary Combustion Chamber***Secondary Combustion Chamber***Smoke Filter Chamber***Optional Wet Scrubber System(1 section or 3 sections)
Email: sales@hiclover.com
Email: hicloversales@gmail.comNanjing Clover Medical Technology Co.,Ltd.
Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult Safty safe safer Incinerator Shape L/ I L Loading manual big door can be by Forklift Land occupation small big Ash door same with feeding door or alone alone market share Most-CHINA/USA/INDIA Few- UK/USA Dooring open type Manual Pry bar/Hydraulic pressure Dooring Open size small big Better for medical bag waste animal waste open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke
parts of an incineratorphysical method of disposing hazardous chemical wasteportable incinerators typesproper ways of waste disposal in the communityquestionnaire to ask about incinerators for collection of dataHICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator
2020-08-07