Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Small incinerators for the solid waste equipment in waste management yard HICLOVER TS150(PLC)

Small incinerators for the solid waste equipment in waste management yard. 

Items/Model

TS150(PLC)

Principle

Waste Incineration Treatment

Burn Rate

Average 50-100 kg/hour

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4(D.O)

Thermal capacity(kw/hour)

166-332

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)

Incinerator comprising of a two-stage unit of a primary loading chamber and a secondary after burner chamber. The after-burner system draws hot gases from the primary chamber and ensures a clean burn at 850-1150 degrees Celsius.
Primary Chambe「 volume (m3) Not less than 1.54
Load capacity (kg) Not less than 750
Nominal burn rate (kg/hr) Less than 50
Burn Rate (kg/hr) Plus 50
Thermal capacity (kw/hr) Plus or minus 190
Power supply 50/60hz 210/230v
Diesel Yes
Prefabricated robust mild steel casing not less than lOmm, seam welded and suitably stiffened I braced where necessary. Steel structured painted using high grade paint system. Primary and secondary chamber lining thickness of not less than 180mm, rated at 1430 degrees Celsius. At least three layers of
paint standard as 800 Celsius. thickness 164mm, rated 1750 Celsius
refractory lining in the primary and secondary chambers of not less than 180mm total thickness providing increase fuel efficiency. Lightweight resilient refractory fibre insulation lid providing a tight seal giving thermal efficiency. Weather proof combustion fuel pipes and electrical systems to resist marine type of weather.
Primary Chamber:
Fully insulated internal refractory lining,constructed from high grade refractory brick. High alumina content refractory bricks. Manual operated access lid. Waste ignition burner, temperature controlled on and off with internal air fans. heavy duty 价ebrick 1750 Celsius by wall. refractory cement by Secondary Chamber: bottom and toρ.
Fully insulated internal refractory lining,constructed from high grade low thermal mass insulation. Secondary chamber burnout burner, temperature controlled on and off with internal air fans. Integrated combustion burner air fans with an automatically controlled distribution. Temperature sensor mounted
at the top of the chamber ensuring the chamber reaches the necessary temperature 850I 1100 Degrees Celsius minimum. heavy duty firebrick 1750 Celsius by wall. refractory cement by bottom and toρ.
operation temperature 1000-1200 Celsius
Waste loading and De-Ashing:Loading through the main access door. At the end of every incineration, ash should be discharged through the loading door.primarv chamber: feedina door臼lso ash door). secondary chamber:

HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Nanjing Clover Medical Technology Co.,Ltd.



 

2020-07-08

Mobile Cremation Equipment

Model

CA-200

Picture

Burning Rate

Average 100 kgs/hour

Primary Combustion Chamber

2000 Liters

Secondary Combustion Chimney

Yes

Feed Mode

Manual

Voltage

220V

Power

3.0 Kw

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 53 kg/hour

Internal Dimensions

230 x 100 x 90cm (primary chamber)

External Dimensions

290 x 200 x 170cm (primary chamber)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

500 Liters

Door Opening

90 x 90cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

9000 kgs(with container)

Operation Technical Specifications

Paimary Chamber Temperature

800–1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal


Mobile crematorium 
HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22

Incinerators QA

Q: what is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No.GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.
Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000usd per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat) Website: www.hiclover.com Email: sales@hiclover.com Email: hicloversales@gmail.com

Items/ModelTS10(PLC)TS20(PLC)TS30(PLC)TS50(PLC)TS100(PLC) Burn Rate (Average)10 kg/hour20 kg/hour30 kg/hour50 kg/hour100 kg/hour Feed Capacity(Average)20kg40kg60kg100kg200 kg Control ModePLCPLCPLCPLCPLC Combustion Chamber100L210L330L560L1200L Internal Dimensions50x50x40cm65x65x50cm75x75x60cm100x80x70cm120x100x100cm Secondary Chamber50L110L180L280L600L Smoke Filter ChamberYesYesYesYesYes Feed ModeManualManualManualManualManual Voltage220V220V220V220V220V Power0.5Kw0.5Kw0.5Kw0.7Kw0.7Kw Oil Consumption (kg/hour)5.4–12.67.8–16.310.2–2012.1–2414–28 Gas Consumption (m3/hour)6.2–11.48–15.79.8–209.9–26.110–32.2 Temperature MonitorYesYesYesYesYes Temperature ProtectionYesYesYesYesYes Oil Tank100L100L100L100L200L Feed Door30x30cm45x40cm55x50cm70x55cm80x60cm Chimney3Meter3Meter5Meter5Meter10Meter Chimney TypeStainless SteelStainless SteelStainless SteelStainless SteelStainless Steel 1st. Chamber Temperature800℃–1000℃800℃–1000℃800℃–1000℃800℃–1000℃800℃–1000℃ 2nd. Chamber Temperature1000℃-1200℃1000℃-1200℃1000℃-1200℃1000℃-1200℃1000℃-1200℃ Residency Time2.0 Sec.2.0 Sec.2.0 Sec.2.0 Sec.2.0 Sec. Gross Weight1500kg2200kg3000kg4500kg6000kg External Dimensions140x90x120cm160x110x130cm175x120x140cm230x130x155cm260x150x180cm


About Hiclover Medical Enviromental

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.
We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.

Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.


The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.


The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.
The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We a re trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.


We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.

Required Specifications for Mobile Incinerator

Operational Capabilities

 

  • PROCESS MINIMUM 1 TON PER DAY
  • OPERATED WITH LIMITED TRAINING
  • REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING
  • COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
  • ABILITY TO BURN WASTE LUBRICANTS (POL)
  • HANDLE ORGANIC SOLIDS (TO INCLUDE RMW)
  • DEPLOYABLE
  • MOBILE
  • 24 HRS OF CONTINUOUS USE
  • AUTOMATIC LOADING SYSTEM
  • AUTOMATED ASH REMOVAL SYSTEM
  • GAS SCRUBBING SYSTEM
  • 95% REDUCTION OF SOLID WASTE
  • OPERATE OFF DIESEL OR FUEL OIL
  • CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
  • ABLE TO TAKE ALL COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, WOOD
  • NO PRE-TREATMENT OF WASTE REQUIRED
  • FIVE (5) YEAR COMPONENT WARRANTY

 

 

Technical Specifications

 

  • OPERATION MANUAL AND TRAINING MANUAL FOR EACH INCINERATOR
  • SET UP AND INSTALLATION INSTRUCTION MANUALS
  • BLUE PRINT/ SCHEMATIC PROVIDED THAT OUTLINES THE PHYSICAL DIMENSIONS OF THE 20’ INCINERATORS
  • INCINERATORS COMPOSED WITH HEAVY DUTY WELDED CONSTRUCTION
  • OPERATED AND TRANSPORTED IN 20’ INCINERATORS (CONTAINERS)
  • FULL FRONT AND OPTIONAL REAR ACCESS
  • PRIMARY / SECONDARY TEMPERATURE CONTROLS

Clover's Social Media